How to use the BTU calculator
- Choose whether you want to cool or heat the room.
- Enter the length and width of the room in feet, or its area.
- For cooling, say how sunny the room is, how many people usually use it, and whether it is a kitchen.
- Read the BTUs per hour. Choose a unit close to this size, not much bigger.
How cooling size is worked out
The calculator uses the room air conditioner sizing chart published by ENERGY STAR, which assumes an 8 foot ceiling:
| Area to be cooled | Capacity needed |
|---|---|
| 100 to 150 sq ft | 5,000 BTU/hr |
| 150 to 250 sq ft | 6,000 BTU/hr |
| 250 to 300 sq ft | 7,000 BTU/hr |
| 300 to 350 sq ft | 8,000 BTU/hr |
| 350 to 400 sq ft | 9,000 BTU/hr |
| 400 to 450 sq ft | 10,000 BTU/hr |
| 450 to 550 sq ft | 12,000 BTU/hr |
| 550 to 700 sq ft | 14,000 BTU/hr |
| 700 to 1,000 sq ft | 18,000 BTU/hr |
| 1,000 to 1,200 sq ft | 21,000 BTU/hr |
| 1,200 to 1,400 sq ft | 23,000 BTU/hr |
| 1,400 to 1,500 sq ft | 24,000 BTU/hr |
| 1,500 to 2,000 sq ft | 30,000 BTU/hr |
| 2,000 to 2,500 sq ft | 34,000 BTU/hr |
Then it makes the same adjustments ENERGY STAR recommends:
- Heavily shaded room: reduce capacity by 10%.
- Very sunny room: increase capacity by 10%.
- More than two people: add 600 BTU for each extra person.
- Kitchen: add 4,000 BTU.
Worked example
A living room 15 by 20 feet is 300 square feet, which falls in the 300 to 350 row: 8,000 BTU. If it is very sunny, add 10% for 8,800 BTU. If four people usually use it, add 2 × 600 = 1,200 BTU, for a total of 10,000 BTU.
Why bigger is not better
An air conditioner that is too large cools the room quickly and switches off before it has removed much moisture, so the room can feel cold and damp. It also cycles on and off more, which wastes energy. Pick the size closest to the result.
Heating estimate
Heating needs depend much more on insulation, windows and climate. A common rough guide is 30 to 60 BTU per square foot, from warm to very cold climates. A 300 square foot room in a moderate climate needs about 300 × 40 = 12,000 BTU/hr. For a whole house, a heating and cooling contractor should do a proper load calculation (Manual J).
BTUs, tons and watts
- 12,000 BTU per hour = 1 ton of cooling
- 1 BTU per hour = 0.293 watts
- A 12,000 BTU unit moves about 3.5 kW of heat
To measure an odd-shaped room, use the square footage calculator.
Frequently asked questions
What size air conditioner do I need for a 300 square foot room?
About 7,000 to 8,000 BTU. ENERGY STAR's chart lists 7,000 BTU for 250 to 300 square feet and 8,000 BTU for 300 to 350, before adjusting for sun, people and kitchens.
How many BTUs per square foot do I need?
For cooling, roughly 20 BTU per square foot for a typical room with an 8 foot ceiling. The chart above is more precise, especially for small rooms.
Is a bigger air conditioner better?
No. An oversized unit cools too quickly, leaves the room damp and wastes energy by switching on and off. Choose the size closest to the result.
How many BTUs is 1 ton of air conditioning?
12,000 BTU per hour. A 2 ton system is 24,000 BTU and a 3 ton system is 36,000 BTU.
What about high ceilings?
The chart assumes 8 foot ceilings. For 10 foot ceilings, many people scale up by the ratio, about 25% more, but a contractor can check the exact load.